AeroCool Rigid Media Cooler – Ultra-efficient 4×4 Wet Sections
4×4 Hi-Density Media Highest efficiency provides for the most cooling Specification of critical components is vital in obtaining the required discharge volume through the unit. Motor horse power, voltage, motor shaft outside diameter, motor sheave outside and inside diameter all directly relate to the revolutions per minute (RPM) of the blower wheel. Equally important is the reduction in electrical usage …
Master Blaster – Image Resource
[sspalbum id=”36″]
MasterBlaster – Dimensional Data
Master Blaster The Master Blaster is available in two sizes MB24 – 6,500 cfm, 1/2 HP – 2 spd MB36 -10,000 cfm, 3/4 HP – 2 spd Chassis Features All Steel Construction Exclusive PMI Peblar XT Finish 18.5ft Power Cord Heavy Duty Castors – 2 Locking 2-Speed Operation Fully Assembled Fan Features Licensed for Sound & Air Performance …
Aerocool Sheave, Motor and Pump Specifications
Sheave & Motor Selection All sheaves listed are adjustable to meet the blower speed RPM requirements for your application. Using the model number combined with the motor horsepower and blower RPM, use this chart to locate the corresponding part number in the far right column. Motors of varying and identical horse power may have different motor shaft sizes. Be certain …
EcoKool – Image Resource
[sspalbum id=”31″]
Winterizing Panel – Image Resource
[sspalbum id=”30″]
EcoKool – How it Works
How EcoKool Works Stage 1 Hot outside air is drawn into EcoKool and passes through a high efficiency rigid media. Stage 2 Moisture from the cool air is drawn away as it passes through the drying stage. Stage 3 Cool dry air is supplied to the air conditioner coils where it creates the ideal environment for your air conditioner to …
CoolTool – Image Resource
[sspalbum id=6]
Single Point Connection – Image Resource
[sspalbum id=25]
Single Point Connection – Specifications
Single Point Connection Specifications Factory Pre-wire Service includes installation and wiring of the motor, motor sheave, pump, float, control box and the pump junction box. The control box for the SPC is ready for the 120V pump supply wire and the motor voltage supply. For the SPCR the control box is wired for only 240V motor AND pump. Order process …
AeroCool Commercial Fan Cooler – Image Resource
[sspalbum id=24]
AeroCool Commercial Fan Cooler – Dimensional Data
[table id=29 /]
AeroCool Commercial Fan Cooler – Technical Data
[table id=28 /] [table id=13 /] Performance certified is for installation type B: free inlet, ducted outlet. Performance ratings include the effect of evaporative media. Power (BHP) includes transmission losses. All external wiring and components such as disconnects, motor starters, and over-current protection are to be field supplied and are not included as part of the evaporative cooler from the …
AeroCool Blower Cooler – Image Resource
[sspalbum id=15]
Commercial Aspen Fan Cooler – Image Resource
[sspalbum id=16]
Commercial Aspen Fan Coolers – Dimensional Data
[table id=21 /]
Commercial Aspen Fan Cooler – Technical Data
[table id=20 /] [table id=13 /] Performance certified is for installation type B: free inlet, ducted outlet. Performance ratings include the effect of evaporative media. Power (BHP) includes transmission losses. All external wiring and components such as disconnects, motor starters, and over-current protection are to be field supplied and are not included as part of the evaporative cooler from the …
Frigiking Aspen Coolers – Image Resources
[sspalbum id=”13″]
Frigiking Aspen Coolers – Dimensional Data
[table id=19 /]
Frigiking Aspen Coolers – Specifications
Commercial Cooler Technical Information Performance shows they insulation type B – free inlet, duct outlet, power Rating (B.H.P.) does not include driver losses. Performance ratings include the effects of evaporative media in the airstream [table id=14 /] [table id=13 /] [table id=15 /] Sheave Selection All sheaves listed are adjustable to meet the blower speed RPM requirements for your application. …
Frigiking Aspen Coolers – Performance
Energy Efficiency & Exceptional Performance Specification of critical components is vital in obtaining the required discharge volume through the unit. Motor horsepower, voltage, motor shaft outside diameter, motor sheave outside and inside diameter all directly relate to the revolutions per minute (RPM) of the blower wheel. Equally important is the reduction in electrical usage and water required for operation. The …
Brisa Window Cooler – Image Resource
[sspalbum id=11]
Aerocool Pro Series – Image Resource
[sspalbum id=”9″]
Aerocool Pro Series – Dimensional Data
[table id=12 /] Specifying U.L. Listed Models When specifying or ordering U.L. Listed models, add a “U” prefix to the front of the appropriate model number. In order to maintain this U.L. designation, these models must be used in conjunction with PMI supplied motor kits and pumps. Example: UPD4802
Aerocool Pro Series – Specifications
Choosing the right Pro-Series Choosing the right Pro-Series model is important for proper operation. For maximum performance, choose the model with the proper rating and motor as well as the correct duct configuration. Ask your qualified contractor to help you choose the correct Pro-Series model that best fits your home and your needs. [table id=11 /]
Trophy Series – Image Resource
[sspalbum id=”8″]
Trophy Series – Dimensional Data
[table id=42 /]
Aerocool Pro – Features & Benefits
Benefits of the Aerocool® Pro Series Pro-4×4 Media Pro-4×4 Media (1) This high-efficiency blend of media delivers colder air than any other home comfort evaporative cooler sold today. Pro-Armor (2) The premier single inlet cooler with polymeric inner structure that completely shields the wet section from corrosive interaction. Easy Access Gravity-Held Doors (3) Easy to remove access doors reduce maintenance …
FrigiKing – Dimensional Data
[table id=7 /]
Frigiking – Models & Specifications
[table id=2 /] Specifying UL Listed Models When specifying or ordering U.L. Listed models, add a “U” prefix to the front of the appropriate model number. In order to maintain this U.L. Listed designation, these models must be used in conjunction with PMI supplied motor kits and pumps. Example: UFD650
Frigiking – Features & Benefits
Features & Benefits Finishing Process PMI’s exclusive MIRROSCOPIC Blower shaft finish process yields a 90% improvement over the industry standard “ground finish”. This means quieter operation as well as longer bearing and shaft life for your cooler! Easy Access Gravity-Held Doors Easy to remove access doors reduce maintenance time. Easy Setup Junction box allows for easy plug-in connections of motor …
Frigiking – Image Resource
[sspalbum id=”7″]
Why does my new rigid media cooler smell bad and how do I stop it from smelling?
When water is first introduced to the cooler the glue that holds the media together may emit an odor that smells offensive. This smell will go away after the media has been soaked well and rinsed. Run the pump long enough to wet out the pads and then dump the water. Repeat the process. Finally you can add a cap …
Are the residential motors thermally protected?
Yes, all of the residential cooler motors that we use are thermally protected.
What is the difference between the Aerocool Trophy and the Aerocool Pro Series?
The Trophy Series is the base model of the Pro Series. The Pro Series units come with all the extra goodies such as Power Cleaning System, Pro-Stat (Thermostat) and Winterizing Panel and the motor comes factory installed and pre-wired.
Are thermostats available for evaporative coolers?
Yes. PMI™’s Aerocool Pro Series Cooler is equipped with its own specific thermostat designed specially for that model. Additionally, PMI now offers The Nth Degree (NDS) which is UL-listed, easy to install and works with any cooler that is 115V or 230V and has up to 1 horsepower motors.
What is an UP-DUX?
Up-dux is a ceiling vent which allows the air to pass through the attic area and out through the roof vents. When the cooler comes on, the air pressure automatically opens the up-dux barometric dampers and when the cooler shuts off, the damper automatically closes.
What is evaporative cooling?
Nature’s most efficient means of cooling is through the evaporation of water. Evaporative cooling works on the principle of heat absorption by moisture evaporation. The evaporative cooler draws exterior air into special pads soaked with water, where the air is cooled by evaporation, then circulated into your space.
How do I direct the cooled air blown into my house?
Other than the direction of the vents, you can control the flow of air by opening the windows or doors of different rooms that you want to pull the air into.
Why evaporative cooling?
Evaporative cooling has gained rapid acceptance because the process relies solely on water evaporation with extremely low energy consumption to produce a significant amount of cooling. Evaporative cooling will generally pay for itself (including installation) in just a few seasons. This equates to a great investment for consumers who on the average own the same home for 5-6 years. Also …
Is there another way to exhaust the air other than leaving windows or doors open?
Yes. You may install up-dux vents to exhaust the air through your attic and out the roof vents. By exhausting cool air through the attic, you can reduce the temperature of this hot spot and make your home more comfortable. It is important to remember to provide adequate exhaust in the attic area. Provide 2 sq. ft. of relief for every …
How many windows or doors do I need to leave open?
You should open your windows until the air pressure inside the house is nearly balanced with the air outside. One method used to determine when air is reasonably balanced is to place a tissue paper against the screen in the window furthest from the cooler and adjust the opening of the other windows in the house until the tissue paper …
What is exhaust air?
The evaporative cooler draws fresh exterior air through special pads soaked with water. The air is cooled, filtered and circulated through the home. The hot, stale air needs to exit and this is referred to as “relief air”. The best “relief” design is to exhaust slightly less air then your cooler is supplying. This will ensure that your home has a slight positive …
What is the difference between Aspen pads and Rigid Media pads?
Aspen pads are made of shredded aspen wood and are approximately 75% efficient. Rigid Media pads are made of glued together cellulous material that is honeycomb in shape and the standard product is approximately 85% efficient.
AeroCool Commercial Rigid Media Cooler – Dimensional Data
[table id=24 /] [table id=26 /]
AeroCool Commercial Cooler – 8in Wet Section Technical Data
8” Standard Media Economical choice – Lower Replacement Cost Specification of critical components is vital in obtaining the required discharge volume through the unit. Motor horsepower, voltage, motor shaft outside diameter, motor sheave outside and inside diameters all directly relate to the revolutions per minute (RPM) of the blower wheel. Equally important is the reduction in electrical usage and water …
AeroCool Blower Cooler – 12in Wet Section Technical Data
12” Standard Media High efficiency – More surface area for better cooling Phoenix Manufacturing, Inc. certifies that the evaporative coolers shown are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Specification of critical components is …
AeroCool Blower Cooler – Performance Data
Energy Efficiency & Exceptional Performance Specification of critical components is vital in obtaining the required discharge volume through the unit. Motor horsepower, voltage, motor shaft outside diameter, motor sheave outside and inside diameters all directly relate to the revolutions per minute (RPM) of the blower wheel. Equally important is the reduction in electrical usage and water required for operation. Aerocool …
CoolTool – Multi-Purpose Cooler
Mobile or Permanent Installation Options A multi-purpose unit in the 4600 CFM* range, the CoolTool V2 (CTV21) can be configured with its adjustable mounting legs, for permanent through-the-wall installation, or with the included casters for mobile cooling. The extra tall design allows you to adjust the air flow to a convenient height and two extra large pads provide optimum air …
CoolTool – Mobile Coolers
Powerful Cooling On Wheels Powerful 1/3 HP, 115 Volt, 2 Speed Motor Dual Inlet Design, for Easy Maintenance Twin 360º Multi-directional Grilles Simple controls and Quiet operation Peblar-XT Finish Easy Caster Assembly
Brisa Portable – PAC120-G
Cool up to 200 Square Feet 7 hr Timer 2.7 Gallon Capacity Water Tank Easy Remove & Fill Water Tank Adjustable grille fins and oscillation function for better air delivery Usages only 60w of Power Dimensions: 25”H x 15”W x 11”L
Brisa Portable – PAC200-F
Cool up to 250 Square Feet 7hr Timer 1.5 Gallon Capacity Water Tank Easy Remove & Fill Water Tank Adjustable grille fins and oscillation function for better air delivery Usages only 75w of Power Dimensions: 26.5”H x 15”W x 10.5”L
Brisa Portable – PAC390-A
Cool up to 500 Square Feet 12hr Timer Digital Display 5.5 Gallon Capacity Water Tank Wider wind angle for wider cooling coverage Usages only 103w of Power Dimensions: 30.5”H x 18.5”W x 12”L
Brisa Ducted Cooler – Image Resource
[sspalbum id=”10″]
Brisa Ducted Cooler – Models & Specifications
[table id=32 /] [table id=33 /]
Trophy Series – Specifications
[table id=8 /] Specifying U.L. Listed models When specifying U.L. Listed models, add a “U” prefix to the front of the model number. These models require the use of PMI supplied motor kits and pumps. Example: UTD4801
Brisa Window Cooler – Models & Specifications
Models: BW4002, BW4502, BW5002, RBW5001 Model: WH2905 Model: BW3004, BW3501 [table id=34 /] [table id=46 /]
Brisa Ducted Cooler – Features & Benefits
Features & Benefits Finishing Process PMI’s exclusive MIRROSCOPIC Blower shaft finish process yields a 90% improvement over the industry standard “ground finish”. This means quieter operation as well as longer bearing and shaft life for your cooler! Easy Access Gravity-Held Doors Easy to remove access doors reduce maintenance time. Easy Setup Junction box allows for easy plug-in connections of motor …
Trophy Series – Features & Benenfits
Benefits of the Aerocool Trophy Series High Efficiency Rigid Media The Aerocool® evaporative cooler beats the others cold — it is more efficient and less costly to operate. In fact, it is up to 13% more efficient than conventional coolers. Rigid media material provides cooler air and can last up to 10 times longer than old style aspen pads. Pro-Armor …
Brisa Window Cooler – Features & Benefits
Features & Benefits 10 year Warranty against leaks due to rust out Finishing Process PMI’s exclusive MIRROSCOPIC Blower shaft finish process yields a 90% improvement over the industry standard “ground finish”. This means quieter operation as well as longer bearing and shaft life for your cooler! Easy Access Gravity-Held Doors Easy to remove access doors reduce maintenance time. Easy Setup …