Check the set screws on the blower assembly hub, If loose, follow this procedure. If the setscrew is loose on the opposite of the pulley side, untighten the set screw so that is not touching the shaft, then grab blower wheel assembly and pull the assembly against the leather washer and bearing, with palm of your hand shove the blower …
What causes noise at water supply line?
¼” copper tubing when not secured to solid surface near cooler will cause water hammering, all the way down the copper tubing to where it is connected to solid supply line. Secure 1/4”copper tubing with rubberize hose clamp. On AeroCool coolers, secure ¼” tubing within 18” where tubing is attached to side of wet section.
What causes the motor to shut down and overheat and then come back on after cooling down?
If motor sheave is not properly adjusted the motor will overheat and shut off until it cools down. On all window and mobile models, operating the unit without front discharge grill in place will cause the motor to over heat and shut off until it cools down.
Why does my new rigid media cooler smell bad and how do I stop it from smelling?
When water is first introduced to the cooler the glue that holds the media together may emit an odor that smells offensive. This smell will go away after the media has been soaked well and rinsed. Run the pump long enough to wet out the pads and then dump the water. Repeat the process. Finally you can add a cap …
There is a smell coming from my cooler what should I do?
Drain, flush and clean the reservoir. Ensure the cooler has a bleed-off or Power Cleaning System installed. You may need to clean or replace pads. If you have new pads you should run your pump with out the blower for a period of time to wash out some of the smell, during which time you also dump the sump of …
Why is the water draining from the overflow stand pipe?
If the water is not coming from the bleed-off or Power Cleaning System™s systematic flushing you may need to adjust the float or replace it. Refer to the Owner’s Manual for float adjustment instructions.
Why is my cooler not cooling?
You may have inadequate exhaust. Open more windows or doors. For every 1,000 CFM of air delivery 2 sq. ft. of unrestricted air relief is required. Check the water distribution system to make sure there is sufficient water to the pads and check pads to ensure they are not clogged. If pads are not wet, check to see if recirculating pump is operating. …